Friday, May 31, 2013

Week 9: Concluding Analysis

Most of the analysis and data collection is done, we have:

Resistivity (m2oC/kW)
Loss/year (kWhr.)
Installation ($)
Cellulose
5429
122,992
237,464
Fiberglass batt
4319
156,396
164,915
Polystyrene
6333
106,660
142,560
The % lost is the percent of added heat lost with the type of insulation covering a 14000sqft/floor, 6 floor commercial building in Philadelphia.


We still need to figure out how much money we are saving each month with the types of insulation.

Wednesday, May 22, 2013

Week 8: Final testing and Analysis

During this week we will finish our final tests on the different kinds of insulation. With the results that we received from the test we now will have the  thermal resistivity of each each insulation. Although one insulation may have shown to have a better thermal resistivity it may not be economically plausible. We have found through the economic analysis that the price to install any of the insulation will require a bank loan. What we plan to accomplish by the end of the week, or beginning of the following week, is if we can save money through one of the particular insulation.
We have calculated the amount of electricity that a building similar to ours would regenerate in a years time. We have also focused that electricity to find how much of it is put into heating and cooling. We then found the cost to heat and cool a building in the Philadelphia region for an entire year. We plan on using this data to find if it is plausible to install one of our insulations. 
Also, this week we plan on having a risk analysis completed. To show what risks may come up when installing the material or future risks. 

Wednesday, May 15, 2013

Week 7: Continuing Testing and Analysis


  This week we continued testing (testing takes a while with our project due to each test taking multiple hours). We started testing the cellulose and did more tests on the polystyrene and fiberglass insulation. We also started to wait for about an hour before turning off the heat source, light bulb, so that the temperature of the box would be stabilized. Then we began our testing so that our data would be more accurate and would not have a curve at the beginning.
  We were able to use the results we had gotten to figure out the thermal resistivity of each insulation measured in m2/W as well as the costs of each insulation for a building of six floors with 14,000 sqrft/floor. We figured out the cost efficiency of each insulation from the information we had gotten. We also did some risk analysis of the whole project as well as the risk analysis of each component of the project.
A couple of graphs we had:

Wednesday, May 8, 2013

Week 6: Continuing testing


This past week we conducted several tests outside of lab. The polystyrene box was tested and the fiberglass batt box was tested. Unfortunately there was a problem in our testing procedure; we did not allow the box’s temperature to become steady before taking data to calculate the cooling curve. Because of this we will be retesting and analyzing the data for these two boxes this next week. We will also be beginning the economic analysis.

The testing procedure follows: the box is sealed and a light bulb is turned on for an hour. The light bulb is then unplugged and the box begins to cool. The cadence of internal temperature data collection differs for each type of insulation, but it follows the form of: every half minute for twenty minutes, ever minute for forty minutes, ever two minutes for an hour, and every five minutes for an hour or two. The data is then analyzed with the equation γ=ln[(Tin(f) - Tout)/(Tinitial,in – Tout)]. The data is then plotted t VS γ, and a linear trend-line is applied. The slope of the trend line is proportional to the thermal conductivity, which is the inverse of the resistance, or insulating ability of the material.

Sunday, May 5, 2013

Week 5: Beginning Initial Testing

     This week we began to do our initial testing. In class we set up our first experiment. We inserted out light bulb into the sheet rock and also made a tiny hole for the thermocouple. We had one end of the thermocouple inside of the sheet rock to tell us the temperature inside. The other end was outside of the unit to measure the temperature of the room. We then surrounded the sheet rock with our first insulation, Styrofoam. When everything was secure we turned on the light bulb and watched the temperature rise. Since time was running short we let the temperature rise to about twenty degrees about room temperature. Then turned off the light source and recorded the degree difference every thirty seconds.
   This test was not an official test. It was in the place to get a feel for the length of time it would take to do each experiment. Also, to see how difficult it was to maintain each experiment. Later in the week the  Styrofoam will be tested again for an official read. The fiber glass will also be tested.
   The most difficult part of doing these experiments is maintain consistency when testing. We have to make sure that the area where we are testing remains consistent. This will help us reduce our amount of error.